AISYSCFGPOWER-MIB :: aiSCPowerAgregateStatus

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › AISYSCFGPOWER-MIB › aiSCPowerAgregateStatus

aiSCPowerAgregateStatus

Module: AISYSCFGPOWER-MIB

OID (symbolic): AISYSCFGPOWER-MIB::aiSCPowerAgregateStatus

OID (numeric): 1.3.6.1.4.1.539.32.3.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Aggregate status of the power in the system. okay(1) indicates no problems, while trouble(2) indicates that some part of the power supply system is not functioning properly.

What is aiSCPowerAgregateStatus?

Indicates the overall health of the entire power supply system, returning okay(1) when all components are functioning normally or trouble(2) when any part of the power infrastructure has a fault. This is a quick top-level check for power system problems.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.539.32.3.1
snmpwalk -v2c -c public <target> AISYSCFGPOWER-MIB::aiSCPowerAgregateStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.539.32.3.1.1
snmpget -v2c -c public <target> AISYSCFGPOWER-MIB::aiSCPowerAgregateStatus.1

Start monitoring Applied Innovation network access equipment (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the AISYSCFGPOWER-MIB::aiSCPowerAgregateStatus OID value, configure state conditions and alerts, and monitor any Applied Innovation network access equipment (legacy) from a single console.

How to Use in IPNetwork Monitor

Select an Applied Innovation network access equipment (legacy) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type aiSCPowerAgregateStatus into the Find box to locate it in the OID tree, then select it and click OK. It reports the aggregate status of the power in the system. okay(1) indicates no problems, while trouble(2) indicates that some part of the power supply system is not functioning properly. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than 'okay', since that indicates the condition this object reports has changed to one worth investigating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.539aiiAI193TX-MIB
1.3.6.1.4.1.539.32aiSysCfgAISYSCFG-MIB
1.3.6.1.4.1.539.32.3aiSysCfgPowerAISYSCFG-MIB
Numeric OIDNameModule
1.3.6.1.4.1.539.32.3.1aiSCPowerAgregateStatusAISYSCFGPOWER-MIB