AISLCDISCRETE-MIB :: aislcdiscPowerSupplyStatus

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsAISLCDISCRETE-MIBaislcdiscPowerSupplyStatus

aislcdiscPowerSupplyStatus

Module: AISLCDISCRETE-MIB

OID (symbolic): AISLCDISCRETE-MIB::aislcdiscPowerSupplyStatus

OID (numeric): 1.3.6.1.4.1.539.24.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Status of the power supply. okay(1) or trouble(2). When the SLC is booted, this indicates okay(1) until the software determines the correct status.

What is aislcdiscPowerSupplyStatus?

Reports the overall status of the device's power supply, indicating either okay or trouble. Upon boot, the status defaults to okay until the software has determined the actual condition.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.539.24.3
snmpwalk -v2c -c public <target> AISLCDISCRETE-MIB::aislcdiscPowerSupplyStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.539.24.3.1
snmpget -v2c -c public <target> AISLCDISCRETE-MIB::aislcdiscPowerSupplyStatus.1

Start monitoring Applied Innovation AIscout/AIscout2 remote telemetry units (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the AISLCDISCRETE-MIB::aislcdiscPowerSupplyStatus OID value, configure state conditions and alerts, and monitor any Applied Innovation AIscout/AIscout2 remote telemetry units (legacy) from a single console.

How to Use in IPNetwork Monitor

Select an Applied Innovation AIscout/AIscout2 remote telemetry unit (legacy) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type aislcdiscPowerSupplyStatus into the Find box to locate it in the OID tree, then select it and click OK. Status of the power supply. okay(1) or trouble(2). On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than 'okay', since that indicates the condition this object reports has changed to one worth investigating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.539aiiAI198CLC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.539.24aiSLCDiscreteAISLCDISCRETE-MIB
1.3.6.1.4.1.539.24.3aislcdiscPowerSupplyStatusAISLCDISCRETE-MIB