Type: WeekMinutes
Access: read-write
Description: Alternatively to a regular polling of the Master Controllers by an SNMP Manager, the Master Controller is capable of sending a regular 'I'm-alive-message' to the A.I.M.O.S. SNMP Agent. In this way, the A.I.M.O.S. SNMP Agent will recognise a failure of the Master Controller when the message is no longer sent and can consequently generate and send out a aimosAlarmNew notification with the objects aimosAlarmListAlarmID set to alarmHeartbeatMissing(63) and aimosAlarmListSpecificProblem set to 8888.
aimosMasterV1HeartbeatInterval is an object of type WeekMinutes, by which the interval at which the Master Controller is to send this 'life sign' can be set. Values from 0 up to 10.080 are allowed.
Setting 0 deactivates the Heartbeat feature, the highest setting 10.080 sets the interval to one week.
What is aimosMasterV1HeartbeatInterval?
This read-write field, measured in minutes (default 0, meaning disabled), sets how often the Master Controller sends an "I'm alive" heartbeat message to the A.I.M.O.S. SNMP Agent instead of waiting to be polled. If a heartbeat is overdue, the agent raises an aimosAlarmNew alarm with aimosAlarmListAlarmID set to alarmHeartbeatMissing(63); valid values run from 0 (heartbeat off) up to 10,080, which is one full week.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6408.201.3.5.13.1.3 snmpwalk -v2c -c public <target> AIMOS::aimosMasterV1HeartbeatInterval
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.6408.201.3.5.13.1.3.1 snmpget -v2c -c public <target> AIMOS::aimosMasterV1HeartbeatInterval.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.6408.201.3.5.13.1.3.1 s <value>
Start monitoring Andrew Wireless Systems DAS/repeater equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the AIMOS::aimosMasterV1HeartbeatInterval OID value, configure state conditions and alerts, and monitor any Andrew Wireless Systems DAS/repeater equipment from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.6408 | mikom | AIMOS |
| 1.3.6.1.4.1.6408.201 | aimos | AIMOS |
| 1.3.6.1.4.1.6408.201.3 | aimosObjects | AIMOS |
| 1.3.6.1.4.1.6408.201.3.5 | aimosUnitManagement | AIMOS |
| 1.3.6.1.4.1.6408.201.3.5.13 | aimosMasterUnitV1Table | AIMOS |
| 1.3.6.1.4.1.6408.201.3.5.13.1 | aimosMasterUnitV1Entry | AIMOS |
| 1.3.6.1.4.1.6408.201.3.5.13.1.3 | aimosMasterV1HeartbeatInterval | AIMOS |