ADVANTECH-EKI-PRONEER-MIB :: xRingProCoupleMasterRingID

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVANTECH-EKI-PRONEER-MIBxRingProCoupleMasterRingID

xRingProCoupleMasterRingID

Module: ADVANTECH-EKI-PRONEER-MIB

OID (symbolic): ADVANTECH-EKI-PRONEER-MIB::xRingProCoupleMasterRingID

OID (numeric): 1.3.6.1.4.1.10297.202.7000.3.14.3.3

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: The master ring ID of X-Ring Pro

What is xRingProCoupleMasterRingID?

This is a read-write integer (1 to 255) setting which X-Ring Pro couple is the master. Master controls failover. Example: set to '1' to make ring 1 the master couple.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.10297.202.7000.3.14.3.3
snmpwalk -v2c -c public <target> ADVANTECH-EKI-PRONEER-MIB::xRingProCoupleMasterRingID

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.10297.202.7000.3.14.3.3.1
snmpget -v2c -c public <target> ADVANTECH-EKI-PRONEER-MIB::xRingProCoupleMasterRingID.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.10297.202.7000.3.14.3.3.1 i <value>

Start monitoring Advantech EKI-series industrial Ethernet switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVANTECH-EKI-PRONEER-MIB::xRingProCoupleMasterRingID OID value, configure state conditions and alerts, and monitor any Advantech EKI-series industrial Ethernet switches from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.10297advantechADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202aSwitchMIBADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000proneerADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.3l2switchingADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.3.14xRingProADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.3.14.3xRingProCoupleSettingADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.3.14.3.3xRingProCoupleMasterRingIDADVANTECH-EKI-PRONEER-MIB