ADVANTECH-EKI-PRONEER-MIB :: xRingEliteRule

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVANTECH-EKI-PRONEER-MIBxRingEliteRule

xRingEliteRule

Module: ADVANTECH-EKI-PRONEER-MIB

OID (symbolic): ADVANTECH-EKI-PRONEER-MIB::xRingEliteRule

OID (numeric): 1.3.6.1.4.1.10297.202.7000.3.12.2.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The rule of the X-Ring Elite

What is xRingEliteRule?

This is a read-write enum selecting X-Ring Elite topology: basic (1), couple (2), tunnel (3), mrm (4), mrc (5), legacy (6). Example: set to 2 for coupled-ring protection.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.10297.202.7000.3.12.2.1.3
snmpwalk -v2c -c public <target> ADVANTECH-EKI-PRONEER-MIB::xRingEliteRule

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.10297.202.7000.3.12.2.1.3.1
snmpget -v2c -c public <target> ADVANTECH-EKI-PRONEER-MIB::xRingEliteRule.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.10297.202.7000.3.12.2.1.3.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> xRingEliteRule.1

Start monitoring Advantech EKI-series industrial Ethernet switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVANTECH-EKI-PRONEER-MIB::xRingEliteRule OID value, configure state conditions and alerts, and monitor any Advantech EKI-series industrial Ethernet switches from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.10297advantechADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202aSwitchMIBADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000proneerADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.3l2switchingADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.3.12xRingEliteADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.3.12.2xRingEliteRingIDTableADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.3.12.2.1xRingEliteRingIDEntryADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.3.12.2.1.3xRingEliteRuleADVANTECH-EKI-PRONEER-MIB