ADVANTECH-EKI-PRONEER-MIB :: stromControlPortState

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVANTECH-EKI-PRONEER-MIBstromControlPortState

stromControlPortState

Module: ADVANTECH-EKI-PRONEER-MIB

OID (symbolic): ADVANTECH-EKI-PRONEER-MIB::stromControlPortState

OID (numeric): 1.3.6.1.4.1.10297.202.7000.5.1.3.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: the state of setting

What is stromControlPortState?

This is a read-write enum (enable=1, disable=2) toggling storm control on a specific port. Example: set to 1 to enable rate limiting on port 4.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.10297.202.7000.5.1.3.1.2
snmpwalk -v2c -c public <target> ADVANTECH-EKI-PRONEER-MIB::stromControlPortState

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.10297.202.7000.5.1.3.1.2.1
snmpget -v2c -c public <target> ADVANTECH-EKI-PRONEER-MIB::stromControlPortState.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.10297.202.7000.5.1.3.1.2.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> stromControlPortState.1

Start monitoring Advantech EKI-series industrial Ethernet switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVANTECH-EKI-PRONEER-MIB::stromControlPortState OID value, configure state conditions and alerts, and monitor any Advantech EKI-series industrial Ethernet switches from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.10297advantechADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202aSwitchMIBADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000proneerADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.5securityADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.5.1stormControlADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.5.1.3stromControlPortTableADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.5.1.3.1stromControlPortEntryADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.5.1.3.1.2stromControlPortStateADVANTECH-EKI-PRONEER-MIB