ADVANTECH-EKI-PRONEER-MIB :: stpBridgeTxHoldCount

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVANTECH-EKI-PRONEER-MIBstpBridgeTxHoldCount

stpBridgeTxHoldCount

Module: ADVANTECH-EKI-PRONEER-MIB

OID (symbolic): ADVANTECH-EKI-PRONEER-MIB::stpBridgeTxHoldCount

OID (numeric): 1.3.6.1.4.1.10297.202.7000.3.8.6.4

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: the Transmit Hold Count used to limit BPDU transmission rate.

What is stpBridgeTxHoldCount?

This is the transmission hold count (1-10) limiting BPDUs per second from a port to prevent overwhelming slower links. Lower values send more BPDUs; higher values transmit less frequently. Example: 6 BPDUs/second is typical.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.10297.202.7000.3.8.6.4
snmpwalk -v2c -c public <target> ADVANTECH-EKI-PRONEER-MIB::stpBridgeTxHoldCount

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.10297.202.7000.3.8.6.4.1
snmpget -v2c -c public <target> ADVANTECH-EKI-PRONEER-MIB::stpBridgeTxHoldCount.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.10297.202.7000.3.8.6.4.1 i <value>

Start monitoring Advantech EKI-series industrial Ethernet switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVANTECH-EKI-PRONEER-MIB::stpBridgeTxHoldCount OID value, configure state conditions and alerts, and monitor any Advantech EKI-series industrial Ethernet switches from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.10297advantechADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202aSwitchMIBADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000proneerADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.3l2switchingADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.3.8stpADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.3.8.6stpBridgeInfoADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.3.8.6.4stpBridgeTxHoldCountADVANTECH-EKI-PRONEER-MIB