All MIBs › ADVANTECH-EKI-PRONEER-MIB › stpBridgePriority
stpBridgePriority
Module: ADVANTECH-EKI-PRONEER-MIB
OID (symbolic): ADVANTECH-EKI-PRONEER-MIB::stpBridgePriority
OID (numeric): 1.3.6.1.4.1.10297.202.7000.3.8.6.1
Node type: OBJECT-TYPE
Type: Integer32
Access: read-write
Description: the Bridge Priority in the CIST instance. Priority support the following value: 0, 4096, 8192, 12288, 16384, 20480, 24576, 28672, 32768, 36864, 40960, 45056, 49152, 53248, 57344, 61440
What is stpBridgePriority?
This sets the STP bridge priority (0, 4096, 8192, ... 61440) used in the root bridge election. Lower values become the root; equal values use MAC address as tiebreaker. Example: set primary to 0, secondary to 4096.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.10297.202.7000.3.8.6.1 snmpwalk -v2c -c public <target> ADVANTECH-EKI-PRONEER-MIB::stpBridgePriority
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.10297.202.7000.3.8.6.1.1 snmpget -v2c -c public <target> ADVANTECH-EKI-PRONEER-MIB::stpBridgePriority.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.10297.202.7000.3.8.6.1.1 i <value>
Start monitoring Advantech EKI-series industrial Ethernet switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVANTECH-EKI-PRONEER-MIB::stpBridgePriority OID value, configure state conditions and alerts, and monitor any Advantech EKI-series industrial Ethernet switches from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.10297 | advantech | ADVANTECH-EKI-PRONEER-MIB |
| 1.3.6.1.4.1.10297.202 | aSwitchMIB | ADVANTECH-EKI-PRONEER-MIB |
| 1.3.6.1.4.1.10297.202.7000 | proneer | ADVANTECH-EKI-PRONEER-MIB |
| 1.3.6.1.4.1.10297.202.7000.3 | l2switching | ADVANTECH-EKI-PRONEER-MIB |
| 1.3.6.1.4.1.10297.202.7000.3.8 | stp | ADVANTECH-EKI-PRONEER-MIB |
| 1.3.6.1.4.1.10297.202.7000.3.8.6 | stpBridgeInfo | ADVANTECH-EKI-PRONEER-MIB |
| 1.3.6.1.4.1.10297.202.7000.3.8.6.1 | stpBridgePriority | ADVANTECH-EKI-PRONEER-MIB |