rmonStatisticsDropEvents

Module: ADVANTECH-EKI-PRONEER-MIB

OID (symbolic): ADVANTECH-EKI-PRONEER-MIB::rmonStatisticsDropEvents

OID (numeric): 1.3.6.1.4.1.10297.202.7000.7.7.1.1.3

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The drop events of RMON Statistics

What is rmonStatisticsDropEvents?

This is a read-only counter of packets dropped by the RMON statistics monitor due to buffer limits. Engineers watch this to detect if monitoring is keeping pace with traffic. Example: 50 drop events indicates monitoring buffer overflow.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.10297.202.7000.7.7.1.1.3
snmpwalk -v2c -c public <target> ADVANTECH-EKI-PRONEER-MIB::rmonStatisticsDropEvents

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.10297.202.7000.7.7.1.1.3.1
snmpget -v2c -c public <target> ADVANTECH-EKI-PRONEER-MIB::rmonStatisticsDropEvents.1

Start monitoring Advantech EKI-series industrial Ethernet switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVANTECH-EKI-PRONEER-MIB::rmonStatisticsDropEvents OID value, configure state conditions and alerts, and monitor any Advantech EKI-series industrial Ethernet switches from a single console.

How to Use in IPNetwork Monitor

Select an Advantech EKI-series industrial Ethernet switch as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type rmonStatisticsDropEvents into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The drop events of RMON Statistics. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.10297advantechADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202aSwitchMIBADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000proneerADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.7managementADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.7.7rmonADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.7.7.1rmonStatisticsTableADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.7.7.1.1rmonStatisticsEntryADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.7.7.1.1.3rmonStatisticsDropEventsADVANTECH-EKI-PRONEER-MIB