All MIBs › ADVANTECH-EKI-PRONEER-MIB › queryMaxResponseInterval
queryMaxResponseInterval
Module: ADVANTECH-EKI-PRONEER-MIB
OID (symbolic): ADVANTECH-EKI-PRONEER-MIB::queryMaxResponseInterval
OID (numeric): 1.3.6.1.4.1.10297.202.7000.3.6.3.4.1.7
Node type: OBJECT-TYPE
Type: Integer32
Access: read-write
Description: In Membership Query Message, it specifies the maximum allowed time before sending a responding report in units of 1/10 second
What is queryMaxResponseInterval?
This is the maximum time (0.5-2.0 seconds in units of 1/10 second) a host has to respond to an IGMP query before the querier assumes the group is inactive. Lower values detect departures faster; higher values reduce query overhead. Example: set to 10 (= 1 second).
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.10297.202.7000.3.6.3.4.1.7 snmpwalk -v2c -c public <target> ADVANTECH-EKI-PRONEER-MIB::queryMaxResponseInterval
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.10297.202.7000.3.6.3.4.1.7.1 snmpget -v2c -c public <target> ADVANTECH-EKI-PRONEER-MIB::queryMaxResponseInterval.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.10297.202.7000.3.6.3.4.1.7.1 i <value>
Start monitoring Advantech EKI-series industrial Ethernet switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVANTECH-EKI-PRONEER-MIB::queryMaxResponseInterval OID value, configure state conditions and alerts, and monitor any Advantech EKI-series industrial Ethernet switches from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.10297 | advantech | ADVANTECH-EKI-PRONEER-MIB |
| 1.3.6.1.4.1.10297.202 | aSwitchMIB | ADVANTECH-EKI-PRONEER-MIB |
| 1.3.6.1.4.1.10297.202.7000 | proneer | ADVANTECH-EKI-PRONEER-MIB |
| 1.3.6.1.4.1.10297.202.7000.3 | l2switching | ADVANTECH-EKI-PRONEER-MIB |
| 1.3.6.1.4.1.10297.202.7000.3.6 | multicast | ADVANTECH-EKI-PRONEER-MIB |
| 1.3.6.1.4.1.10297.202.7000.3.6.3 | igmpSnooping | ADVANTECH-EKI-PRONEER-MIB |
| 1.3.6.1.4.1.10297.202.7000.3.6.3.4 | igmpSnoopingTable | ADVANTECH-EKI-PRONEER-MIB |
| 1.3.6.1.4.1.10297.202.7000.3.6.3.4.1 | igmpSnoopingEntry | ADVANTECH-EKI-PRONEER-MIB |
| 1.3.6.1.4.1.10297.202.7000.3.6.3.4.1.7 | queryMaxResponseInterval | ADVANTECH-EKI-PRONEER-MIB |