ADVANTECH-EKI-PRONEER-MIB :: ledSYSStatus

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVANTECH-EKI-PRONEER-MIBledSYSStatus

ledSYSStatus

Module: ADVANTECH-EKI-PRONEER-MIB

OID (symbolic): ADVANTECH-EKI-PRONEER-MIB::ledSYSStatus

OID (numeric): 1.3.6.1.4.1.10297.202.7000.1.1.14.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The LED status of system operating.

What is ledSYSStatus?

This read-only field shows the system LED status: not supported (0), up/green (1), or down/red (2). Mirrors the physical LED on the device. Value 1 indicates healthy operation.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.10297.202.7000.1.1.14.1
snmpwalk -v2c -c public <target> ADVANTECH-EKI-PRONEER-MIB::ledSYSStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.10297.202.7000.1.1.14.1.1
snmpget -v2c -c public <target> ADVANTECH-EKI-PRONEER-MIB::ledSYSStatus.1

Start monitoring Advantech EKI-series industrial Ethernet switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVANTECH-EKI-PRONEER-MIB::ledSYSStatus OID value, configure state conditions and alerts, and monitor any Advantech EKI-series industrial Ethernet switches from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.10297advantechADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202aSwitchMIBADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000proneerADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.1monitoringADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.1.1deviceInfoADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.1.1.14ledStatusADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.1.1.14.1ledSYSStatusADVANTECH-EKI-PRONEER-MIB