ADVANTECH-EKI-PRONEER-MIB :: factoryDefaultKeepFlag

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVANTECH-EKI-PRONEER-MIBfactoryDefaultKeepFlag

factoryDefaultKeepFlag

Module: ADVANTECH-EKI-PRONEER-MIB

OID (symbolic): ADVANTECH-EKI-PRONEER-MIB::factoryDefaultKeepFlag

OID (numeric): 1.3.6.1.4.1.10297.202.7000.8.5.2

Node type: OBJECT-TYPE

Type: Bits

Access: read-write

Description: Keep setting when switch is restore to factory default.

What is factoryDefaultKeepFlag?

This is a read-write BITS field selecting settings to preserve during factory reset: vlan(1), ipaddress(2), useraccount(3). Engineers use this to retain critical config during reset. Example: ipaddress flag keeps the device IP.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.10297.202.7000.8.5.2
snmpwalk -v2c -c public <target> ADVANTECH-EKI-PRONEER-MIB::factoryDefaultKeepFlag

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.10297.202.7000.8.5.2.1
snmpget -v2c -c public <target> ADVANTECH-EKI-PRONEER-MIB::factoryDefaultKeepFlag.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.10297.202.7000.8.5.2.1 s <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> factoryDefaultKeepFlag.1

Start monitoring Advantech EKI-series industrial Ethernet switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVANTECH-EKI-PRONEER-MIB::factoryDefaultKeepFlag OID value, configure state conditions and alerts, and monitor any Advantech EKI-series industrial Ethernet switches from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.10297advantechADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202aSwitchMIBADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000proneerADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.8diagnosticsADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.8.5factoryDefaultADVANTECH-EKI-PRONEER-MIB
1.3.6.1.4.1.10297.202.7000.8.5.2factoryDefaultKeepFlagADVANTECH-EKI-PRONEER-MIB