ADVA-MIB :: sonetSectionConfigSignalDegradeThreshhold

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-MIBsonetSectionConfigSignalDegradeThreshhold

sonetSectionConfigSignalDegradeThreshhold

Module: ADVA-MIB

OID (symbolic): ADVA-MIB::sonetSectionConfigSignalDegradeThreshhold

OID (numeric): 1.3.6.1.4.1.2544.2.5.4.1.1.1.1.2

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: Block-Error-Based Degradation Definition for SDH (standard integration period). Defined as percentage Background Block Errors (30% default) evaluated over a defined period (SDPER-RS).

What is sonetSectionConfigSignalDegradeThreshhold?

Reports a percentage threshold (0–100%, default 30%) for the background block error rate that triggers a signal degrade alarm. Network operators use this OID to tune the sensitivity of degradation detection, balancing early warning against false alarms. Example value: 25 (indicates a 25% block error threshold for alarm activation).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.2.5.4.1.1.1.1.2
snmpwalk -v2c -c public <target> ADVA-MIB::sonetSectionConfigSignalDegradeThreshhold

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.2.5.4.1.1.1.1.2.1
snmpget -v2c -c public <target> ADVA-MIB::sonetSectionConfigSignalDegradeThreshhold.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.2.5.4.1.1.1.1.2.1 i <value>

Start monitoring ADVA FSP 150 (F3) Carrier Ethernet demarcation devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-MIB::sonetSectionConfigSignalDegradeThreshhold OID value, configure state conditions and alerts, and monitor any ADVA FSP 150 (F3) Carrier Ethernet demarcation devices from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.2commonADVA-MIB
1.3.6.1.4.1.2544.2.5configADVA-MIB
1.3.6.1.4.1.2544.2.5.4transportStandardsADVA-MIB
1.3.6.1.4.1.2544.2.5.4.1sonetADVA-MIB
1.3.6.1.4.1.2544.2.5.4.1.1sonetConfigADVA-MIB
1.3.6.1.4.1.2544.2.5.4.1.1.1sonetSectionConfigTableADVA-MIB
1.3.6.1.4.1.2544.2.5.4.1.1.1.1sonetSectionConfigEntryADVA-MIB
1.3.6.1.4.1.2544.2.5.4.1.1.1.1.2sonetSectionConfigSignalDegradeThreshholdADVA-MIB