All MIBs › ADVA-MIB › oduSectionConfigSignalDegradeThres
oduSectionConfigSignalDegradeThres
Module: ADVA-MIB
OID (symbolic): ADVA-MIB::oduSectionConfigSignalDegradeThres
OID (numeric): 1.3.6.1.4.1.2544.2.5.4.2.2.1.1.1
Node type: OBJECT-TYPE
Type: Integer32
Access: read-write
Description:
Threshold for ODU SM-SD alarm (threshold level 0..100%, default value 15 %. Ref. table 24/G.7710.
What is oduSectionConfigSignalDegradeThres?
This OID reports an integer percentage value (0-100) that sets the threshold below which an ODU Signal Degrade alarm is triggered. It controls alarm sensitivity for the ODU section monitoring, allowing operators to tune detection for their specific quality requirements. A typical value is 15 (representing 15%).
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.2.5.4.2.2.1.1.1 snmpwalk -v2c -c public <target> ADVA-MIB::oduSectionConfigSignalDegradeThres
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.2.5.4.2.2.1.1.1.1 snmpget -v2c -c public <target> ADVA-MIB::oduSectionConfigSignalDegradeThres.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.2.5.4.2.2.1.1.1.1 i <value>
OID Breakdown
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | BIANCA-BRICK-PPP-MIB |
| 1.3.6 | dod | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1 | internet | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4 | private | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4.1 | enterprises | ANIROOT-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.2 | common | ADVA-MIB |
| 1.3.6.1.4.1.2544.2.5 | config | ADVA-MIB |
| 1.3.6.1.4.1.2544.2.5.4 | transportStandards | ADVA-MIB |
| 1.3.6.1.4.1.2544.2.5.4.2 | otn | ADVA-MIB |
| 1.3.6.1.4.1.2544.2.5.4.2.2 | oduConfig | ADVA-MIB |
| 1.3.6.1.4.1.2544.2.5.4.2.2.1 | oduSectionConfigTable | ADVA-MIB |
| 1.3.6.1.4.1.2544.2.5.4.2.2.1.1 | oduSectionConfigEntry | ADVA-MIB |
| 1.3.6.1.4.1.2544.2.5.4.2.2.1.1.1 | oduSectionConfigSignalDegradeThres | ADVA-MIB |