All MIBs › ADVA-FSPR7-PM-MIB › terminPointPhysInstValueOutputPower
terminPointPhysInstValueOutputPower
Module: ADVA-FSPR7-PM-MIB
OID (symbolic): ADVA-FSPR7-PM-MIB::terminPointPhysInstValueOutputPower
OID (numeric): 1.3.6.1.4.1.2544.1.11.11.10.2.1.1.1.3
Node type: OBJECT-TYPE
Type: Integer32
Access: read-only
Description: Instantaneous Optical Power Transmitted (Output)
What is terminPointPhysInstValueOutputPower?
This OID reports instantaneous transmitted optical power at the output port in dBm, tracking real-time laser or transmitter module performance. Monitoring output power verifies the transmitter remains within specification and can detect degrading optical modules before they fail. Example value: -2.8 dBm.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.10.2.1.1.1.3 snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::terminPointPhysInstValueOutputPower
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.10.2.1.1.1.3.1 snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::terminPointPhysInstValueOutputPower.1
Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::terminPointPhysInstValueOutputPower OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.11 | fspR7 | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.11.11 | advaFspR7Pm | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.10 | pmTerminPoint | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.10.2 | pmTerminPointPhysical | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.10.2.1 | pmTerminPointPhysValue | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.10.2.1.1 | terminPointPhysInstValueTable | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.10.2.1.1.1 | terminPointPhysInstValueEntry | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.10.2.1.1.1.3 | terminPointPhysInstValueOutputPower | ADVA-FSPR7-PM-MIB |