ADVA-FSPR7-PM-MIB :: tcmCFacilityHistorical1dayValidFlag

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBtcmCFacilityHistorical1dayValidFlag

tcmCFacilityHistorical1dayValidFlag

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::tcmCFacilityHistorical1dayValidFlag

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.31.1.6

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-only

Description: Valid Flag

What is tcmCFacilityHistorical1dayValidFlag?

This OID reports a boolean flag indicating whether the historical 1-day performance data for TCM C is valid and reliable for statistical analysis. Operators use this flag to determine if the collection period completed normally without interruptions, allowing them to confidently include or exclude the data from SLA reports. A concrete example value would be 1 (true), signifying that the entire 24-hour collection period was valid; a value of 0 would indicate corrupted or incomplete data.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.31.1.6
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::tcmCFacilityHistorical1dayValidFlag

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.31.1.6.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::tcmCFacilityHistorical1dayValidFlag.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::tcmCFacilityHistorical1dayValidFlag OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.31tcmCFacilityHistorical1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.31.1tcmCFacilityHistorical1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.31.1.6tcmCFacilityHistorical1dayValidFlagADVA-FSPR7-PM-MIB