ADVA-FSPR7-PM-MIB :: tcmCFacilityHistorical1daySES

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBtcmCFacilityHistorical1daySES

tcmCFacilityHistorical1daySES

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::tcmCFacilityHistorical1daySES

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.31.1.3

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: ODU Tandem Connection Monitoring C Severely Errored Seconds

What is tcmCFacilityHistorical1daySES?

Reports a 32-bit unsigned integer counter of Severely Errored Seconds (SES) recorded in a completed historical 1-day measurement window for the ODU circuit. Daily historical SES archives support monthly and quarterly SLA compliance reports, helping operators identify circuits requiring maintenance or replacement. Example value: 12 historical 1-day SES indicates a past 24-hour period contained 12 seconds total of severe synchronization failures distributed across that day.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.31.1.3
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::tcmCFacilityHistorical1daySES

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.31.1.3.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::tcmCFacilityHistorical1daySES.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::tcmCFacilityHistorical1daySES OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.31tcmCFacilityHistorical1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.31.1tcmCFacilityHistorical1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.31.1.3tcmCFacilityHistorical1daySESADVA-FSPR7-PM-MIB