ADVA-FSPR7-PM-MIB :: tcmCFacilityHistorical15minSES

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBtcmCFacilityHistorical15minSES

tcmCFacilityHistorical15minSES

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::tcmCFacilityHistorical15minSES

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.29.1.3

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: ODU Tandem Connection Monitoring C Severely Errored Seconds

What is tcmCFacilityHistorical15minSES?

Reports a 32-bit unsigned integer counter of Severely Errored Seconds (SES) from a completed historical 15-minute measurement window. Historical SES data archive supports performance audits, incident correlation, and helps determine if recent problems represent recurring failures or isolated events. Example value: 6 historical SES indicates a past 15-minute period experienced 6 seconds of severe synchronization loss or complete frame failure.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.29.1.3
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::tcmCFacilityHistorical15minSES

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.29.1.3.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::tcmCFacilityHistorical15minSES.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::tcmCFacilityHistorical15minSES OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.29tcmCFacilityHistorical15minTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.29.1tcmCFacilityHistorical15minEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.29.1.3tcmCFacilityHistorical15minSESADVA-FSPR7-PM-MIB