ADVA-FSPR7-PM-MIB :: tcmBFacilityHistorical1dayValidFlag

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBtcmBFacilityHistorical1dayValidFlag

tcmBFacilityHistorical1dayValidFlag

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::tcmBFacilityHistorical1dayValidFlag

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.23.1.6

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-only

Description: Valid Flag

What is tcmBFacilityHistorical1dayValidFlag?

Reports a boolean or enumerated flag confirming whether this 24-hour historical performance snapshot is complete and suitable for SLA reporting. This flag prevents erroneous availability calculations when collection was interrupted due to system reboot, SNMP unavailability, or other data loss events. Valid values are 0 (incomplete/invalid) or 1 (full 24-hour window collected).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.23.1.6
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::tcmBFacilityHistorical1dayValidFlag

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.23.1.6.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::tcmBFacilityHistorical1dayValidFlag.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::tcmBFacilityHistorical1dayValidFlag OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.23tcmBFacilityHistorical1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.23.1tcmBFacilityHistorical1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.23.1.6tcmBFacilityHistorical1dayValidFlagADVA-FSPR7-PM-MIB