ADVA-FSPR7-PM-MIB :: tcmAFacilityCurrent15minSES

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBtcmAFacilityCurrent15minSES

tcmAFacilityCurrent15minSES

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::tcmAFacilityCurrent15minSES

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.9.1.2

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: ODU Tandem Connection Monitoring A Severely Errored Seconds

What is tcmAFacilityCurrent15minSES?

This object reports a 32-bit counter of Severely Errored Seconds for TCM Layer A during the current 15-minute period. High SES counts in the 15-minute window indicate acute signal quality problems or equipment failures affecting the monitored connection; a single TCM A SES burst often triggers immediate escalation and may initiate automatic protection switching. Example values might be 0 during normal conditions or 15-50 during a signal degradation event.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.9.1.2
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::tcmAFacilityCurrent15minSES

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.9.1.2.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::tcmAFacilityCurrent15minSES.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::tcmAFacilityCurrent15minSES OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.9tcmAFacilityCurrent15minTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.9.1tcmAFacilityCurrent15minEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.9.1.2tcmAFacilityCurrent15minSESADVA-FSPR7-PM-MIB