ADVA-FSPR7-PM-MIB :: sarLinkRcvFacilityCurrent15minES

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBsarLinkRcvFacilityCurrent15minES

sarLinkRcvFacilityCurrent15minES

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::sarLinkRcvFacilityCurrent15minES

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.201.1.1

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: SAR Link Receive ES

What is sarLinkRcvFacilityCurrent15minES?

This object reports a non-negative integer counter representing Errored Seconds (ES) on the SAR link receive path during the current 15-minute collection interval. ES on the receive side indicates incoming transmission quality problems originating from the far-end transmitter, helping isolate where link degradation occurs. A concrete example might show 2 errored seconds in the current 15-minute window, signaling recent receive-side quality issues.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.201.1.1
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::sarLinkRcvFacilityCurrent15minES

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.201.1.1.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::sarLinkRcvFacilityCurrent15minES.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::sarLinkRcvFacilityCurrent15minES OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.201sarLinkRcvFacilityCurrent15minTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.201.1sarLinkRcvFacilityCurrent15minEntryADVA-FSPR7-PM-MIB