ADVA-FSPR7-PM-MIB :: rndTrpDlyFacilityHistorical1weekHigh

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBrndTrpDlyFacilityHistorical1weekHigh

rndTrpDlyFacilityHistorical1weekHigh

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::rndTrpDlyFacilityHistorical1weekHigh

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.2.3.23.1.4

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: Measured round trip delay high

What is rndTrpDlyFacilityHistorical1weekHigh?

This object captures the worst-case round-trip delay measured during a 7-day period, reflecting peak-hour congestion or transient anomalies across the entire week. Network operators use the weekly high to assess whether peak-time latency consistently violates SLAs and to prioritize capacity upgrades or congestion mitigation efforts. A typical example value would be 42 milliseconds if the circuit experienced sustained congestion during the business week peak hours.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.23.1.4
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::rndTrpDlyFacilityHistorical1weekHigh

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.23.1.4.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::rndTrpDlyFacilityHistorical1weekHigh.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::rndTrpDlyFacilityHistorical1weekHigh OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2pmFacilityPhysicalADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3pmFacilityPhysRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.23rndTrpDlyFacilityHistorical1weekTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.23.1rndTrpDlyFacilityHistorical1weekEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.23.1.4rndTrpDlyFacilityHistorical1weekHighADVA-FSPR7-PM-MIB