ADVA-FSPR7-PM-MIB :: pcs4FacilityCurrent15minES

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBpcs4FacilityCurrent15minES

pcs4FacilityCurrent15minES

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::pcs4FacilityCurrent15minES

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.81.1.1

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: Physical Coding Layer Errored Seconds

What is pcs4FacilityCurrent15minES?

Reports the count of errored seconds (each second containing at least one transmission error) for the PCS4 interface during the current rolling 15-minute window. Real-time monitoring of this metric alerts operators to active degradation requiring immediate investigation. Example: A value of 18 means 18 seconds in the current 15-minute window have contained transmission errors.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.81.1.1
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::pcs4FacilityCurrent15minES

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.81.1.1.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::pcs4FacilityCurrent15minES.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> pcs4FacilityCurrent15minES.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::pcs4FacilityCurrent15minES OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.81pcs4FacilityCurrent15minTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.81.1pcs4FacilityCurrent15minEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.81.1.1pcs4FacilityCurrent15minESADVA-FSPR7-PM-MIB