ADVA-FSPR7-PM-MIB :: pcs3FacilityHistorical15minCVDE

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBpcs3FacilityHistorical15minCVDE

pcs3FacilityHistorical15minCVDE

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::pcs3FacilityHistorical15minCVDE

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.77.1.3

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-only

Description: Physical Coding Layer Coding Violations + Disparity Errors

What is pcs3FacilityHistorical15minCVDE?

Reports an unsigned integer counter of coding violations and disparity errors detected at the Physical Coding Sublayer during a 15-minute historical interval. This metric identifies physical layer transmission errors that degrade signal quality and indicate potential link degradation or electromagnetic interference on the optical interface. Example: A value of 127 means 127 coding/disparity errors were recorded during that 15-minute historical period.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.77.1.3
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::pcs3FacilityHistorical15minCVDE

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.77.1.3.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::pcs3FacilityHistorical15minCVDE.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::pcs3FacilityHistorical15minCVDE OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.77pcs3FacilityHistorical15minTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.77.1pcs3FacilityHistorical15minEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.77.1.3pcs3FacilityHistorical15minCVDEADVA-FSPR7-PM-MIB