ADVA-FSPR7-PM-MIB :: pcs1FacilityHistorical1daySE

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBpcs1FacilityHistorical1daySE

pcs1FacilityHistorical1daySE

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::pcs1FacilityHistorical1daySE

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.63.1.4

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: Sync Header Errors Physical Coding Layer

What is pcs1FacilityHistorical1daySE?

Reports a Counter32 value representing Sync Header errors—framing errors at the Physical Coding Layer—accumulated over 24 hours. This metric indicates loss of link synchronization or scrambler misalignment and triggers urgent troubleshooting if trending upward. Example: 240 Sync Header Errors suggests potential signal integrity issues that may cause link flaps.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.63.1.4
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::pcs1FacilityHistorical1daySE

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.63.1.4.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::pcs1FacilityHistorical1daySE.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::pcs1FacilityHistorical1daySE OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.63pcs1FacilityHistorical1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.63.1pcs1FacilityHistorical1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.63.1.4pcs1FacilityHistorical1daySEADVA-FSPR7-PM-MIB