All MIBs › ADVA-FSPR7-PM-MIB › pcs1FacilityCurrent1dayElapsedTime
pcs1FacilityCurrent1dayElapsedTime
Module: ADVA-FSPR7-PM-MIB
OID (symbolic): ADVA-FSPR7-PM-MIB::pcs1FacilityCurrent1dayElapsedTime
OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.59.1.4
Node type: OBJECT-TYPE
Type: Integer32
Access: read-only
Description: Elapsed 1Day
What is pcs1FacilityCurrent1dayElapsedTime?
This OID reports the elapsed time in seconds since the current 24-hour measurement interval began, typically a value between 0 and 86,400 seconds. In network monitoring, elapsed time confirms whether the current daily baseline is partial or complete, influencing confidence in threshold decisions. An example value might be 43200, indicating exactly 12 hours (43,200 seconds) into the current day's collection.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.59.1.4 snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::pcs1FacilityCurrent1dayElapsedTime
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.59.1.4.1 snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::pcs1FacilityCurrent1dayElapsedTime.1
Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::pcs1FacilityCurrent1dayElapsedTime OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.11 | fspR7 | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.11.11 | advaFspR7Pm | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7 | pmFacility | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1 | pmFacilityData | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2 | pmFacilityDataRecord | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2.59 | pcs1FacilityCurrent1dayTable | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2.59.1 | pcs1FacilityCurrent1dayEntry | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2.59.1.4 | pcs1FacilityCurrent1dayElapsedTime | ADVA-FSPR7-PM-MIB |