ADVA-FSPR7-PM-MIB :: pcs1FacilityCurrent15minES

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBpcs1FacilityCurrent15minES

pcs1FacilityCurrent15minES

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::pcs1FacilityCurrent15minES

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.57.1.1

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: Physical Coding Layer Errored Seconds

What is pcs1FacilityCurrent15minES?

This OID reports a counter value representing the number of errored seconds accumulated during the current 15-minute measurement interval at the Physical Coding Layer. In network monitoring, PCS ES detects second-level coding layer violations and helps identify intermittent path issues or fiber plant degradation. A typical value might be 2, indicating 2 seconds within the current 15-minute window contained PCS errors.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.57.1.1
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::pcs1FacilityCurrent15minES

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.57.1.1.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::pcs1FacilityCurrent15minES.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> pcs1FacilityCurrent15minES.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::pcs1FacilityCurrent15minES OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.57pcs1FacilityCurrent15minTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.57.1pcs1FacilityCurrent15minEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.57.1.1pcs1FacilityCurrent15minESADVA-FSPR7-PM-MIB