ADVA-FSPR7-PM-MIB :: otuFecFacilityCurrent15minUBE

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBotuFecFacilityCurrent15minUBE

otuFecFacilityCurrent15minUBE

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::otuFecFacilityCurrent15minUBE

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.41.1.4

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-only

Description: OTU FEC Uncorrected Block Errors

What is otuFecFacilityCurrent15minUBE?

Reports an integer counter of uncorrected block errors where the FEC decoder detected error patterns it could not fully correct in the current 15-minute interval. These failures indicate segments of data that suffered unrecoverable corruption and represent potential loss of network traffic. Example value: 2 (indicating 2 data blocks exceeded FEC correction capability in the current period).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.41.1.4
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::otuFecFacilityCurrent15minUBE

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.41.1.4.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::otuFecFacilityCurrent15minUBE.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> otuFecFacilityCurrent15minUBE.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::otuFecFacilityCurrent15minUBE OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.41otuFecFacilityCurrent15minTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.41.1otuFecFacilityCurrent15minEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.41.1.4otuFecFacilityCurrent15minUBEADVA-FSPR7-PM-MIB