Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::oscGainOptMuxHistorical1dayTimeStamp

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.17.2.3.9.1.6

Node type: OBJECT-TYPE

Type: DateAndTime

Access: read-only

Description: Timestamp

What is oscGainOptMuxHistorical1dayTimeStamp?

This object reports a timestamp counter marking the end of the 24-hour Optical Service Channel gain statistical collection interval. For network monitoring, this daily timestamp allows correlation of OSC performance with specific dates and enables automated daily reporting and archival. A concrete example value would be 1688256000 (Unix epoch, representing midnight UTC) or a device counter like 86400000 milliseconds.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.17.2.3.9.1.6
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::oscGainOptMuxHistorical1dayTimeStamp

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.17.2.3.9.1.6.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::oscGainOptMuxHistorical1dayTimeStamp.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::oscGainOptMuxHistorical1dayTimeStamp OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.17pmOptMuxADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.17.2pmOptMuxPhysicalADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.17.2.3pmOptMuxPhysRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.17.2.3.9oscGainOptMuxHistorical1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.17.2.3.9.1oscGainOptMuxHistorical1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.17.2.3.9.1.6oscGainOptMuxHistorical1dayTimeStampADVA-FSPR7-PM-MIB