ADVA-FSPR7-PM-MIB :: optMuxPhysThresholdPumpLaser4TempLowThres

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBoptMuxPhysThresholdPumpLaser4TempLowThres

optMuxPhysThresholdPumpLaser4TempLowThres

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::optMuxPhysThresholdPumpLaser4TempLowThres

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.17.2.2.1.1.10

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Laser 4 temperature fixed low threshold

What is optMuxPhysThresholdPumpLaser4TempLowThres?

Reports an integer temperature value in degrees Celsius defining the minimum acceptable operating temperature for pump laser 4 to maintain performance. In network monitoring, falling below this threshold may signal refrigeration malfunction or environmental exposure, requiring immediate attention to prevent cascading system degradation. A typical example is 5°C representing the lower thermal operating boundary.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.17.2.2.1.1.10
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::optMuxPhysThresholdPumpLaser4TempLowThres

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.17.2.2.1.1.10.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::optMuxPhysThresholdPumpLaser4TempLowThres.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::optMuxPhysThresholdPumpLaser4TempLowThres OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.17pmOptMuxADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.17.2pmOptMuxPhysicalADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.17.2.2pmOptMuxPhysThresholdADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.17.2.2.1optMuxPhysThresholdTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.17.2.2.1.1optMuxPhysThresholdEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.17.2.2.1.1.10optMuxPhysThresholdPumpLaser4TempLowThresADVA-FSPR7-PM-MIB