Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::optFacilityHistorical1weekLow

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.2.3.5.1.2

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Optical Output Power Transmitted

What is optFacilityHistorical1weekLow?

This OID reports the minimum optical output power transmitted over a 1-week historical period, returning a floating-point value measured in decibels relative to 1 milliwatt (dBm). In network monitoring, it identifies the lowest transmit power level reached during the week, helping operators detect potential signal degradation or power regulation issues. A typical value might be -5 dBm, indicating the transmitter output dropped to that minimum threshold.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.5.1.2
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::optFacilityHistorical1weekLow

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.5.1.2.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::optFacilityHistorical1weekLow.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::optFacilityHistorical1weekLow OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2pmFacilityPhysicalADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3pmFacilityPhysRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.5optFacilityHistorical1weekTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.5.1optFacilityHistorical1weekEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.5.1.2optFacilityHistorical1weekLowADVA-FSPR7-PM-MIB