ADVA-FSPR7-PM-MIB :: oprFacilityHistorical1dayLow

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBoprFacilityHistorical1dayLow

oprFacilityHistorical1dayLow

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::oprFacilityHistorical1dayLow

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.2.3.9.1.2

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Optical Input Power Received

What is oprFacilityHistorical1dayLow?

This OID tracks the minimum optical input power received over a 24-hour period, expressed as a dBm floating-point value. For network monitoring, the daily low reveals worst-case signal conditions that day and helps predict equipment failure windows. A realistic example is -20 dBm.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.9.1.2
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::oprFacilityHistorical1dayLow

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.9.1.2.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::oprFacilityHistorical1dayLow.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::oprFacilityHistorical1dayLow OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2pmFacilityPhysicalADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3pmFacilityPhysRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.9oprFacilityHistorical1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.9.1oprFacilityHistorical1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.9.1.2oprFacilityHistorical1dayLowADVA-FSPR7-PM-MIB