ADVA-FSPR7-PM-MIB :: oduFacilityHistorical1dayValidFlag

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBoduFacilityHistorical1dayValidFlag

oduFacilityHistorical1dayValidFlag

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::oduFacilityHistorical1dayValidFlag

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.7.1.6

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-only

Description: Valid Flag

What is oduFacilityHistorical1dayValidFlag?

This object reports a read-only flag (typically enumerated as valid=1 or invalid=0) indicating whether the 1-day historical ODU statistics are valid and complete. The flag is set to invalid if the measurement period was interrupted (device restart, NTP sync, or incomplete 24-hour collection), signaling to management systems whether the aggregated counters can be reliably used for trend analysis. Example values are simply 0 (invalid/incomplete data) or 1 (valid/complete 24-hour period).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.7.1.6
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::oduFacilityHistorical1dayValidFlag

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.7.1.6.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::oduFacilityHistorical1dayValidFlag.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::oduFacilityHistorical1dayValidFlag OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.7oduFacilityHistorical1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.7.1oduFacilityHistorical1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.7.1.6oduFacilityHistorical1dayValidFlagADVA-FSPR7-PM-MIB