ADVA-FSPR7-PM-MIB :: oduFacilityHistorical1daySES

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBoduFacilityHistorical1daySES

oduFacilityHistorical1daySES

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::oduFacilityHistorical1daySES

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.7.1.3

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: ODU Severely Errored Seconds

What is oduFacilityHistorical1daySES?

This object reports a 32-bit counter of Severely Errored Seconds (SES) for an ODU facility during a historical 1-day period. A Severely Errored Second is defined as a 1-second interval where the error rate exceeds a critical threshold (typically more than 30% error events), indicating severe signal degradation. Monitoring SES is critical for identifying catastrophic link failures or fiber cuts, as a single high SES count usually warrants immediate investigation, with example values ranging from 0 to 86400.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.7.1.3
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::oduFacilityHistorical1daySES

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.7.1.3.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::oduFacilityHistorical1daySES.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::oduFacilityHistorical1daySES OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.7oduFacilityHistorical1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.7.1oduFacilityHistorical1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.7.1.3oduFacilityHistorical1daySESADVA-FSPR7-PM-MIB