All MIBs › ADVA-FSPR7-PM-MIB › oduFacilityHistorical1dayES
oduFacilityHistorical1dayES
Module: ADVA-FSPR7-PM-MIB
OID (symbolic): ADVA-FSPR7-PM-MIB::oduFacilityHistorical1dayES
OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.7.1.2
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-only
Description: ODU Errored Seconds
What is oduFacilityHistorical1dayES?
This object reports a 32-bit counter of Errored Seconds (ES) for an ODU facility accumulated over a historical 1-day period. In optical transport networks, an Errored Second is a 1-second interval containing at least one error event (bit error, CRC failure, or frame alignment error). This metric is essential for detecting ODU link degradation and triggering maintenance alerts when error rates exceed acceptable thresholds, with typical thresholds ranging from 0 to 86400 seconds (one full day) depending on service agreements.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.7.1.2 snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::oduFacilityHistorical1dayES
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.7.1.2.1 snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::oduFacilityHistorical1dayES.1
Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::oduFacilityHistorical1dayES OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.11 | fspR7 | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.11.11 | advaFspR7Pm | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7 | pmFacility | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1 | pmFacilityData | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2 | pmFacilityDataRecord | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2.7 | oduFacilityHistorical1dayTable | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2.7.1 | oduFacilityHistorical1dayEntry | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2.7.1.2 | oduFacilityHistorical1dayES | ADVA-FSPR7-PM-MIB |