ADVA-FSPR7-PM-MIB :: oduFacilityCurrent1daySES

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBoduFacilityCurrent1daySES

oduFacilityCurrent1daySES

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::oduFacilityCurrent1daySES

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.3.1.2

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: ODU Severely Errored Seconds

What is oduFacilityCurrent1daySES?

Reports an unsigned integer count of severely errored seconds for the ODU facility during the current 24-hour collection interval. Elevated daily SES indicates consistent service degradation requiring SLA review and remediation. Example value: 45 (45 seconds of severe errors over current 24-hour window).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.3.1.2
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::oduFacilityCurrent1daySES

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.3.1.2.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::oduFacilityCurrent1daySES.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::oduFacilityCurrent1daySES OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.3oduFacilityCurrent1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.3.1oduFacilityCurrent1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.3.1.2oduFacilityCurrent1daySESADVA-FSPR7-PM-MIB