ADVA-FSPR7-PM-MIB :: lbcnFacilityHistorical1weekMean

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBlbcnFacilityHistorical1weekMean

lbcnFacilityHistorical1weekMean

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::lbcnFacilityHistorical1weekMean

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.2.3.17.1.3

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: Laser Bias Current Normalized

What is lbcnFacilityHistorical1weekMean?

Reports an integer percentage value (0-100%) representing the average laser bias current normalized over seven full days of operation. Weekly mean bias current provides a reliable baseline for detecting progressive laser aging and capacity planning for replacement cycles. An example value would be 71 (indicating the laser ran at an average of 71% of nominal bias throughout the entire week).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.17.1.3
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::lbcnFacilityHistorical1weekMean

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.17.1.3.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::lbcnFacilityHistorical1weekMean.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::lbcnFacilityHistorical1weekMean OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2pmFacilityPhysicalADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3pmFacilityPhysRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.17lbcnFacilityHistorical1weekTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.17.1lbcnFacilityHistorical1weekEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.17.1.3lbcnFacilityHistorical1weekMeanADVA-FSPR7-PM-MIB