ADVA-FSPR7-PM-MIB :: lbcnFacilityHistorical1dayValidFlag

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBlbcnFacilityHistorical1dayValidFlag

lbcnFacilityHistorical1dayValidFlag

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::lbcnFacilityHistorical1dayValidFlag

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.2.3.15.1.5

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-only

Description: Valid Flag

What is lbcnFacilityHistorical1dayValidFlag?

Reports a boolean flag (0=invalid, 1=valid) confirming the reliability and completeness of the 24-hour laser bias current statistics for trending and reporting purposes. Invalid flags indicate the measurement was interrupted by module resets, power cycles, or extended service windows during the day. An example value would be 1 (showing that all 24 hours of laser bias data were successfully collected and verified).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.15.1.5
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::lbcnFacilityHistorical1dayValidFlag

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.15.1.5.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::lbcnFacilityHistorical1dayValidFlag.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::lbcnFacilityHistorical1dayValidFlag OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2pmFacilityPhysicalADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3pmFacilityPhysRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.15lbcnFacilityHistorical1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.15.1lbcnFacilityHistorical1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.15.1.5lbcnFacilityHistorical1dayValidFlagADVA-FSPR7-PM-MIB