ADVA-FSPR7-PM-MIB :: lbcnFacilityHistorical1dayHigh

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBlbcnFacilityHistorical1dayHigh

lbcnFacilityHistorical1dayHigh

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::lbcnFacilityHistorical1dayHigh

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.2.3.15.1.4

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: Laser Bias Current Normalized

What is lbcnFacilityHistorical1dayHigh?

Reports an integer percentage value (0-100%) representing the highest laser bias current normalized during the past 24-hour interval. Daily peak bias current identifies peak traffic hours, temperature extremes, or stress conditions that accelerate laser wear and shorten expected service life. An example value would be 91 (representing the single highest bias current percentage recorded during the 24-hour window).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.15.1.4
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::lbcnFacilityHistorical1dayHigh

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.15.1.4.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::lbcnFacilityHistorical1dayHigh.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> lbcnFacilityHistorical1dayHigh.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::lbcnFacilityHistorical1dayHigh OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2pmFacilityPhysicalADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3pmFacilityPhysRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.15lbcnFacilityHistorical1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.15.1lbcnFacilityHistorical1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.15.1.4lbcnFacilityHistorical1dayHighADVA-FSPR7-PM-MIB