ADVA-FSPR7-PM-MIB :: lbcnFacilityHistorical15minHigh

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBlbcnFacilityHistorical15minHigh

lbcnFacilityHistorical15minHigh

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::lbcnFacilityHistorical15minHigh

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.2.3.13.1.4

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: Laser Bias Current Normalized

What is lbcnFacilityHistorical15minHigh?

Reports an integer percentage value (0-100%) representing the highest laser bias current normalized during the most recent 15-minute interval. Elevated bias current peaks can signal thermal transients, high-power transmission bursts, or environmental temperature spikes that stress the laser. An example value would be 88 (representing 88% of nominal laser bias current as the peak observed during the 15-minute measurement).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.13.1.4
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::lbcnFacilityHistorical15minHigh

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.13.1.4.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::lbcnFacilityHistorical15minHigh.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::lbcnFacilityHistorical15minHigh OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2pmFacilityPhysicalADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3pmFacilityPhysRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.13lbcnFacilityHistorical15minTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.13.1lbcnFacilityHistorical15minEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.2.3.13.1.4lbcnFacilityHistorical15minHighADVA-FSPR7-PM-MIB