All MIBs › ADVA-FSPR7-PM-MIB › lbcnFacilityHistorical15minHigh
lbcnFacilityHistorical15minHigh
Module: ADVA-FSPR7-PM-MIB
OID (symbolic): ADVA-FSPR7-PM-MIB::lbcnFacilityHistorical15minHigh
OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.2.3.13.1.4
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-only
Description: Laser Bias Current Normalized
What is lbcnFacilityHistorical15minHigh?
Reports an integer percentage value (0-100%) representing the highest laser bias current normalized during the most recent 15-minute interval. Elevated bias current peaks can signal thermal transients, high-power transmission bursts, or environmental temperature spikes that stress the laser. An example value would be 88 (representing 88% of nominal laser bias current as the peak observed during the 15-minute measurement).
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.13.1.4 snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::lbcnFacilityHistorical15minHigh
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.2.3.13.1.4.1 snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::lbcnFacilityHistorical15minHigh.1
Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::lbcnFacilityHistorical15minHigh OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.11 | fspR7 | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.11.11 | advaFspR7Pm | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7 | pmFacility | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.2 | pmFacilityPhysical | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.2.3 | pmFacilityPhysRecord | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.2.3.13 | lbcnFacilityHistorical15minTable | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.2.3.13.1 | lbcnFacilityHistorical15minEntry | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.2.3.13.1.4 | lbcnFacilityHistorical15minHigh | ADVA-FSPR7-PM-MIB |