ADVA-FSPR7-PM-MIB :: l2PortTxFacilityHistorical15minBytesFrames256Trmt

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBl2PortTxFacilityHistorical15minBytesFrames256Trmt

l2PortTxFacilityHistorical15minBytesFrames256Trmt

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::l2PortTxFacilityHistorical15minBytesFrames256Trmt

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.133.1.10

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-only

Description: 256-511 Byte Frames Transmitted

What is l2PortTxFacilityHistorical15minBytesFrames256Trmt?

Reports a counter of 256-511 byte frames transmitted in a 15-minute historical bucket. This larger-frame metric contributes to frame-size distribution analysis for comprehensive traffic characterization. Example value: 56,234 frames in the 15-minute period.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.133.1.10
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::l2PortTxFacilityHistorical15minBytesFrames256Trmt

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.133.1.10.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::l2PortTxFacilityHistorical15minBytesFrames256Trmt.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::l2PortTxFacilityHistorical15minBytesFrames256Trmt OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.133l2PortTxFacilityHistorical15minTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.133.1l2PortTxFacilityHistorical15minEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.133.1.10l2PortTxFacilityHistorical15minBytesFrames256TrmtADVA-FSPR7-PM-MIB