ADVA-FSPR7-PM-MIB :: l2PortRxFacilityHistorical1dayInterPackJunkBytesFramesRcv

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBl2PortRxFacilityHistorical1dayInterPackJunkBytesFramesRcv

l2PortRxFacilityHistorical1dayInterPackJunkBytesFramesRcv

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::l2PortRxFacilityHistorical1dayInterPackJunkBytesFramesRcv

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.143.1.17

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-only

Description: InterPackJunk Bytes Frames Received (10Gbit/s only)

What is l2PortRxFacilityHistorical1dayInterPackJunkBytesFramesRcv?

This OID counts idle bytes or junk padding inserted between frames on 10 Gbps ports to maintain line rate. It helps detect transmission efficiency or physical layer issues specific to high-speed interfaces. A typical value is 100000000 on active 10G links due to interpacket gaps, or near 0 on idle lines.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.143.1.17
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::l2PortRxFacilityHistorical1dayInterPackJunkBytesFramesRcv

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.143.1.17.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::l2PortRxFacilityHistorical1dayInterPackJunkBytesFramesRcv.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::l2PortRxFacilityHistorical1dayInterPackJunkBytesFramesRcv OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.143l2PortRxFacilityHistorical1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.143.1l2PortRxFacilityHistorical1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.143.1.17l2PortRxFacilityHistorical1dayInterPackJunkBytesFramesRcvADVA-FSPR7-PM-MIB