ADVA-FSPR7-PM-MIB :: l2PortRxFacilityHistorical1dayBytesFrames256Rcv

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBl2PortRxFacilityHistorical1dayBytesFrames256Rcv

l2PortRxFacilityHistorical1dayBytesFrames256Rcv

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::l2PortRxFacilityHistorical1dayBytesFrames256Rcv

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.143.1.13

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-only

Description: 256-511 Byte Frames Received

What is l2PortRxFacilityHistorical1dayBytesFrames256Rcv?

This OID tracks frames of 256–511 bytes, commonly carrying application data with moderate headers (e.g., web requests, file transfers). The distribution of this size class helps identify whether traffic is interactive (smaller) or streaming (larger). Expected range is 500000 frames on a general-purpose link to 100000 on a VoIP trunk.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.143.1.13
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::l2PortRxFacilityHistorical1dayBytesFrames256Rcv

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.143.1.13.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::l2PortRxFacilityHistorical1dayBytesFrames256Rcv.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::l2PortRxFacilityHistorical1dayBytesFrames256Rcv OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.143l2PortRxFacilityHistorical1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.143.1l2PortRxFacilityHistorical1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.143.1.13l2PortRxFacilityHistorical1dayBytesFrames256RcvADVA-FSPR7-PM-MIB