ADVA-FSPR7-PM-MIB :: l2PortRxFacilityHistorical15minBytesFrames1519Rcv

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBl2PortRxFacilityHistorical15minBytesFrames1519Rcv

l2PortRxFacilityHistorical15minBytesFrames1519Rcv

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::l2PortRxFacilityHistorical15minBytesFrames1519Rcv

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.141.1.16

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-only

Description: 1519-Max Byte Frames Received

What is l2PortRxFacilityHistorical15minBytesFrames1519Rcv?

Reports an unsigned integer counter of jumbo frames (exceeding the standard 1518-byte limit) received during the 15-minute window. Jumbo frame usage improves efficiency for bulk storage traffic but requires compatible infrastructure and careful MTU configuration across the network path. Example value: 234567 jumbo frames.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.141.1.16
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::l2PortRxFacilityHistorical15minBytesFrames1519Rcv

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.141.1.16.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::l2PortRxFacilityHistorical15minBytesFrames1519Rcv.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::l2PortRxFacilityHistorical15minBytesFrames1519Rcv OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.141l2PortRxFacilityHistorical15minTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.141.1l2PortRxFacilityHistorical15minEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.141.1.16l2PortRxFacilityHistorical15minBytesFrames1519RcvADVA-FSPR7-PM-MIB