ADVA-FSPR7-PM-MIB :: l2PortRxFacilityCurrent1dayOversizedFramesRcv

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBl2PortRxFacilityCurrent1dayOversizedFramesRcv

l2PortRxFacilityCurrent1dayOversizedFramesRcv

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::l2PortRxFacilityCurrent1dayOversizedFramesRcv

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.139.1.7

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-only

Description: Oversized Frames Received

What is l2PortRxFacilityCurrent1dayOversizedFramesRcv?

This OID reports a count of oversized frames exceeding the standard Ethernet MTU limit, received during the current 24-hour period. Oversized frame detection reveals configuration mismatches (jumbo frame negotiation failures), protocol violations, or edge-case traffic patterns on 10Gbit/s or faster ports. An observation of 145 oversized frames may indicate a misconfigured peer device or legitimate jumbo frame traffic if allowed by policy.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.139.1.7
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::l2PortRxFacilityCurrent1dayOversizedFramesRcv

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.139.1.7.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::l2PortRxFacilityCurrent1dayOversizedFramesRcv.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::l2PortRxFacilityCurrent1dayOversizedFramesRcv OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.139l2PortRxFacilityCurrent1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.139.1l2PortRxFacilityCurrent1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.139.1.7l2PortRxFacilityCurrent1dayOversizedFramesRcvADVA-FSPR7-PM-MIB