ADVA-FSPR7-PM-MIB :: l2PortRxFacilityCurrent1dayCrcErrorsRcv

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBl2PortRxFacilityCurrent1dayCrcErrorsRcv

l2PortRxFacilityCurrent1dayCrcErrorsRcv

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::l2PortRxFacilityCurrent1dayCrcErrorsRcv

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.139.1.5

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-only

Description: Received CRC Errors

What is l2PortRxFacilityCurrent1dayCrcErrorsRcv?

This OID reports a counter representing cyclic redundancy check (CRC) errors detected on received frames during the current 24-hour period. CRC errors indicate bit corruption on the physical link or port, serving as a critical indicator of Layer 2 signal integrity and cable health. A healthy port typically shows 0-2 CRC errors, while 12 or more in a 24-hour period signals potential link degradation requiring investigation.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.139.1.5
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::l2PortRxFacilityCurrent1dayCrcErrorsRcv

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.139.1.5.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::l2PortRxFacilityCurrent1dayCrcErrorsRcv.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::l2PortRxFacilityCurrent1dayCrcErrorsRcv OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.139l2PortRxFacilityCurrent1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.139.1l2PortRxFacilityCurrent1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.139.1.5l2PortRxFacilityCurrent1dayCrcErrorsRcvADVA-FSPR7-PM-MIB