ADVA-FSPR7-PM-MIB :: l2PortRxFacilityCurrent1dayBytesFrames512Rcv

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBl2PortRxFacilityCurrent1dayBytesFrames512Rcv

l2PortRxFacilityCurrent1dayBytesFrames512Rcv

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::l2PortRxFacilityCurrent1dayBytesFrames512Rcv

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.139.1.13

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-only

Description: 512-1023 Byte Frames Received

What is l2PortRxFacilityCurrent1dayBytesFrames512Rcv?

This OID counts frames between 512-1023 bytes received during the current 24-hour measurement interval, capturing larger application payloads before reaching standard MTU. Tracking this range helps identify bulk data transfer sessions and streaming traffic that consume moderate frame sizes. An example count of 4521 frames indicates substantial medium-to-large packet activity.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.139.1.13
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::l2PortRxFacilityCurrent1dayBytesFrames512Rcv

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.139.1.13.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::l2PortRxFacilityCurrent1dayBytesFrames512Rcv.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::l2PortRxFacilityCurrent1dayBytesFrames512Rcv OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.139l2PortRxFacilityCurrent1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.139.1l2PortRxFacilityCurrent1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.139.1.13l2PortRxFacilityCurrent1dayBytesFrames512RcvADVA-FSPR7-PM-MIB