ADVA-FSPR7-PM-MIB :: l2PortRxFacilityCurrent15minCrcErrorsRcv

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBl2PortRxFacilityCurrent15minCrcErrorsRcv

l2PortRxFacilityCurrent15minCrcErrorsRcv

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::l2PortRxFacilityCurrent15minCrcErrorsRcv

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.137.1.5

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-only

Description: Received CRC Errors

What is l2PortRxFacilityCurrent15minCrcErrorsRcv?

Reports a Counter32 of frames with cyclic redundancy check failures, indicating physical layer corruption or electromagnetic interference on the link. CRC errors exceeding single-digit counts over a 15-minute period signal cable degradation, port hardware issues, or duplex mismatch requiring immediate investigation. A healthy port should show 0 CRC errors; even 5 errors suggest potential layer 1 problems that may worsen.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.137.1.5
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::l2PortRxFacilityCurrent15minCrcErrorsRcv

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.137.1.5.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::l2PortRxFacilityCurrent15minCrcErrorsRcv.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::l2PortRxFacilityCurrent15minCrcErrorsRcv OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.137l2PortRxFacilityCurrent15minTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.137.1l2PortRxFacilityCurrent15minEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.137.1.5l2PortRxFacilityCurrent15minCrcErrorsRcvADVA-FSPR7-PM-MIB