ADVA-FSPR7-PM-MIB :: gfpfrFacilityHistorical15minCHecDiscardedFrames

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBgfpfrFacilityHistorical15minCHecDiscardedFrames

gfpfrFacilityHistorical15minCHecDiscardedFrames

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::gfpfrFacilityHistorical15minCHecDiscardedFrames

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.109.1.3

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-only

Description: Core HEC Discarded Frames

What is gfpfrFacilityHistorical15minCHecDiscardedFrames?

This archived counter shows Core HEC frame discards from a past 15-minute interval, enabling retrospective analysis of optical signal quality degradation. By comparing historical HEC errors across intervals, operators can identify patterns indicating fiber aging or environmental stress. An example value of 8 discarded frames from a historical interval reveals that optical impairments were present at that specific time.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.109.1.3
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::gfpfrFacilityHistorical15minCHecDiscardedFrames

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.109.1.3.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::gfpfrFacilityHistorical15minCHecDiscardedFrames.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::gfpfrFacilityHistorical15minCHecDiscardedFrames OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.109gfpfrFacilityHistorical15minTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.109.1gfpfrFacilityHistorical15minEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.109.1.3gfpfrFacilityHistorical15minCHecDiscardedFramesADVA-FSPR7-PM-MIB