ADVA-FSPR7-PM-MIB :: gfpfrFacilityCurrent1dayTHecDiscardedFrames

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsADVA-FSPR7-PM-MIBgfpfrFacilityCurrent1dayTHecDiscardedFrames

gfpfrFacilityCurrent1dayTHecDiscardedFrames

Module: ADVA-FSPR7-PM-MIB

OID (symbolic): ADVA-FSPR7-PM-MIB::gfpfrFacilityCurrent1dayTHecDiscardedFrames

OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.107.1.3

Node type: OBJECT-TYPE

Type: Counter64String

Access: read-only

Description: Type Field HEC Discarded Frames

What is gfpfrFacilityCurrent1dayTHecDiscardedFrames?

This counter accumulates Type Field HEC errors over the current 24-hour period, indicating systematic payload header corruption issues. Daily summation helps identify persistent type-field encoding problems that may require equipment firmware updates or protocol renegotiation. An example value of 23 discarded frames across 24 hours points to intermittent payload classification failures.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.107.1.3
snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::gfpfrFacilityCurrent1dayTHecDiscardedFrames

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.107.1.3.1
snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::gfpfrFacilityCurrent1dayTHecDiscardedFrames.1

Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::gfpfrFacilityCurrent1dayTHecDiscardedFrames OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.11fspR7ADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.11.11advaFspR7PmADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7pmFacilityADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1pmFacilityDataADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2pmFacilityDataRecordADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.107gfpfrFacilityCurrent1dayTableADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.107.1gfpfrFacilityCurrent1dayEntryADVA-FSPR7-PM-MIB
1.3.6.1.4.1.2544.1.11.11.7.1.2.107.1.3gfpfrFacilityCurrent1dayTHecDiscardedFramesADVA-FSPR7-PM-MIB