All MIBs › ADVA-FSPR7-PM-MIB › gfpfrFacilityCurrent1dayTHecDiscardedFrames
gfpfrFacilityCurrent1dayTHecDiscardedFrames
Module: ADVA-FSPR7-PM-MIB
OID (symbolic): ADVA-FSPR7-PM-MIB::gfpfrFacilityCurrent1dayTHecDiscardedFrames
OID (numeric): 1.3.6.1.4.1.2544.1.11.11.7.1.2.107.1.3
Node type: OBJECT-TYPE
Type: Counter64String
Access: read-only
Description: Type Field HEC Discarded Frames
What is gfpfrFacilityCurrent1dayTHecDiscardedFrames?
This counter accumulates Type Field HEC errors over the current 24-hour period, indicating systematic payload header corruption issues. Daily summation helps identify persistent type-field encoding problems that may require equipment firmware updates or protocol renegotiation. An example value of 23 discarded frames across 24 hours points to intermittent payload classification failures.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.107.1.3 snmpwalk -v2c -c public <target> ADVA-FSPR7-PM-MIB::gfpfrFacilityCurrent1dayTHecDiscardedFrames
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.11.11.7.1.2.107.1.3.1 snmpget -v2c -c public <target> ADVA-FSPR7-PM-MIB::gfpfrFacilityCurrent1dayTHecDiscardedFrames.1
Start monitoring ADVA optical transport shelves with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ADVA-FSPR7-PM-MIB::gfpfrFacilityCurrent1dayTHecDiscardedFrames OID value, configure state conditions and alerts, and monitor any ADVA optical transport shelves from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.11 | fspR7 | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.11.11 | advaFspR7Pm | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7 | pmFacility | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1 | pmFacilityData | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2 | pmFacilityDataRecord | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2.107 | gfpfrFacilityCurrent1dayTable | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2.107.1 | gfpfrFacilityCurrent1dayEntry | ADVA-FSPR7-PM-MIB |
| 1.3.6.1.4.1.2544.1.11.11.7.1.2.107.1.3 | gfpfrFacilityCurrent1dayTHecDiscardedFrames | ADVA-FSPR7-PM-MIB |